Home>IEC standards>IEC 60317-38-2013 pdf free download

IEC 60317-38-2013 pdf free download

IEC 60317-38-2013 pdf free download.Specifications for particular types of winding wires – Part 38: Polyester or polyesterimide overcoated with polyamide-imide, enamelled round copper wire, class 200, with a bonding layer.
This part of IEC 60317 specifies the requirements of enamelled round copper winding wire of class 200 with a triple coating. The underlying coating is based on polyester or polyesterimide resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. The secondary coating is based on polyamide-imide resin. The third coating is a bonding layer based on a thermoplastic or thermosetting resin.
NOTE A modified resin Is a resin that has undergone a chemcaI change, or contains one or more addihves to
enhance certain performance or application characterislics.
The range of nominal conductor diameters covered by this part is:
— Grade 1B: 0,050 mm up to and including 1,600 mm:
— Grade 2B: 0,050 mm up to and including 1,600 mm.
The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-1:2013.
2 Normative references
The following documents, in whole or in part, are normatively referenced In this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
IEC 60317-0-1:2013. Specifications for particular types of winding wires — Part 0-1: General requirements — Enamelled round copper wire
3 Terms, definitions, general notes and appearance
3.1 Terms and definitions
Subclause 3.1 of IEC 60317-0-1:2013 applies.
3.2 General notes
3.2.1 Methods of test
Subclause 3.2.1 of IEC 60317-0-1:2013 applies. In case of inconsistencies between IEC 60317-0-1:2013 and this part of IEC 60317, the latter shall prevail.
3.2.2 Winding wire
Class 200 is a thermal class that requires a minimum temperature index of 200 and a heat shock temperature of at least 220 °C.
3.3 Appearance
Subclause
3.3 of IEC 60317-0-1:2013 applies.
4 Dimensions
Clause 4 of IEC 60317-0-1:2013 applies.
5. Electrical resistance
Clause 5 of IEC 60317-0-1:2013 applies.
6 Elongation
Clause 6 of IEC 60317-0-1:2013 applies.
7 Springiness
Clause 7 of IEC 60317-0-1:2013 applies.
8 Flexibility and adherence
Clause 8 of IEC 60317-0-1:2013 applies. For 8.4, the constant K used for the calculation of the number of revolutions for the peel test shall be 1 10 mm.IEC 60317-38 pdf download.