IEC 60675-2018 pdf free.Household electric direct acting room heaters – Methods for measuring performance.
The following normative document contains provisions which, through reference in this text, constitute provisions of this standard. At the time of publication, the edition indicated was valid. All normative documents are subject to revision, and parties to agreements based on this standard are encouraged to investigate the possibility of applying the most recent edition of the normative document indicated below. Members of IEC and ISO maintain registers of currently valid International Standards.
lEG 60584-1: 1977. Thermocouples — Part 1: Refererce tables.
NOTE — Informative references (bibliography) are given in annex D.
3 Definitions
For the purposes of this standard, the following definitions apply:
3.1 direct-acting room heater
appliance which converts electrical energy into heat after a demand for heat has arisen in a room and transfers this heat to the room without delay
NOTE — In this standard, a dIrect-acting room heater Is referred to as a heater.
4 Classification
4.1 According to type
— panel heater;
— convector heater;
— fan heater;
— radiant heater;
— visibly glowing radiant heater.
The type of heater shall be slated.
NOTE 1 — A heater may be a combination of two or more types.
NOTE 2 — If there is doubt regarding the type of heater, the temperature rise of the relevant surfaces is determined.
NOTE 3— Examples of types of heaters are shown in figure 1.
4.2 According to regulating features
— heater without regulation;
— heater with adjustable power input;
— heater with regulated air flow (fan heaters only);
— heater with an ambient temperature thermostat;
— heater with a programmer; -heater with a set-back device:
— heater with frost protection means.
If the heater has features such as means for connection to an external control, details are to
be stated.
NOTE — An example is a heater having means for receiving an external signal for operating the set-back devi.
A heater may have more than one regulating feature.
The regulating features of the heater shall be stated.
5 List of measurements
Performance is determined by means of the following measurements:
一dimensions and mass of the heater, length of the supply cord (clause 7).IEC 60675 pdf free download.