Home>IEC standards>IEC 61058-2-1-2018 pdf free

IEC 61058-2-1-2018 pdf free

IEC 61058-2-1-2018 pdf free.Switches for appliances – Part 2-1: Particular requirements for cord switches.
9 Protection against electric shock
Clause 9 of IEC 61058-1:2016 is applicable except as follows:
9.1 Addition at the end of the subclause:
For cord switches, the test is made when the switch is fitted with cords either of the smallest or of the largest nominal cross-sectional area specified in Table 4, whichever is more unfa vourable.
9.1.2 Replacement:
9.1.2 If a cover or cover plate or a fuse can be removed without the use of a tool, the protection against contact with live parts shall be assured even after removal of the cover or cover plate.
If there is a marking on the outside of the switch showing that a fuse is inside and the cover or cover plate has to be removed with a tool, the protection against contact with live parts shall be assured even after removal of the cover or cover plate.
If there is no marking on the outside of the switch but the instruction sheet shows that a fuse is inside and the cover or cover plate has to be removed with a tool, either the protection against contact with live parts shall be assured even after removal of the cover or cover plate, or the instruction sheet shall state that the disconnection from the supply before opening shall be performed.
Compliance is checked with the standard test finger. test probe B according to IEC 61032.
Addition:
9.101 Non-rewirable switches are tested with the cords as fitted by the manufacturer.
10 Provision for earthing
Clause 10 of IEC 61058-1:2016 is applicable except as follows:
10.1 Addition:
Terminals provided for earthing continuity are permitted if they are separated from live parts by basic insulation and from accessible parts by supplementary insulation. An example of the insulation system for earthing continuity is given in Figure 105.
10.3 Subclause 10.3 of IEC 61058-1:2016 does not apply. Additional subclause:
10.101 The printed conductors of printed circuit boards may be used to provide earthing continuity under the following conditions:
— at least two tracks are used with independent soldering points and the switch complies with 10.4 for each track;
— the material of the printed circuit board consists of epoxide woven glass fabric copper-clad laminated sheet;
— the printed conductors withstand the short circuit test according to Clause 23 of IEC 61058-1-2:2016.IEC 61058-2-1 pdf download.