IEC 61557-6-2019 pdf free.Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. – Equipment for testing, measuring or monitoring of protective
measures – Part 6: Effectiveness of residual current devices (RCD) in TT, TN and IT systems.
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
IEC 61010-1:2010, Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 1: General requirements
IEC 61010-1:2010!AMD1:20161
IEC 61010-2-030:2017, Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 2-030: Particular requirements for equipment having testing or measuring circuits
IEC 61010-031, Safety requirements for electrical equipment for measurement, control and laboratory use — Part 031: Safety requirements for hand-held and hand-manipulated probe assemblies for electrical test and measurement
IEC 6 1557-1 :20 19, Electrical safety in low voltage distribution systems up to 1 000 V AC and
1 500 V DC — Equipment for testing, measuring or monitoring of protective measures — Part 1:
General requirements
3 Terms and definitions
For the purposes of this document, the terms and definitions given in IEC 61557-1 and the following apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
• IEC Electropedia: available at http://www.electropedia.org/
• ISO Online browsing platform: available at http:Ilwww.iso.orglobp
3.1 earth fault current current flowing to earth due to an insulation fault
(SOURCE: IEC 60050-442:1998. 442-01-23]
3.2 residual current 1 RMS value of the vector sum of the currents flowing through the main circuit of the residual current device
(SOURCE: IEC 60050-442:1998. 442-05-19, modified — in alignment with the use in this document. The symbol has been modified.)
3.3 rated residual operating current An fault current for which the residual current is designed
3.4 residual operating current a value of residual current which causes the residual current device to operate under specified conditions
(SOURCE: IEC 60050-442:1998. 442-05-20, modified — The symbol has been added.]
3.5 leakage current electric current in an unwanted conductive path to earth under normal operating conditions
(SOURCE: IEC 60050-195:1998, 195-05-15, modified — to earth has been added and the deprecated term “earth current” omitted.)IEC 61557-6 pdf free download.