Home>IEC standards>IEC 62384-2011 pdf free

IEC 62384-2011 pdf free

IEC 62384-2011 pdf free.DC or AC supplied electronic control gear for LED modules – Performance requirements.
4General notes on tests
4.1 The tests according to this standard are type tests.
NOTE The requirements and tolerances permitted by this standard are based on testing of a type test samplesubmitted by the manufacturer for that purpose. In principle this type test sample should consist of units havingcharacteristics typical of the manufacturer’s production and be as close to the production centre point values aspossible.
lt may be expected with the tolerances given in the standard that products manufactured in accordance with thetype test sample will comply with the standard for the majority of the production. Due to the production spreadhowever,it is inevitable that there will sometimes be products outside the specified tolerances.For guidance ofsampling plans and procedures for inspection by attributes,see IEC 60410.
4.2For tests which are carried out with a LED module or LED modules,this (these) LEDmodule(s) shall fulfil the following requirements:
The wattage of the LED module(s) when measured at its(their) rated voltage or rated current(d.c.and/or a.c.) shall not differ from the rated wattage by more than +6 % and -0 %.
4.3 The tests shall be carried out in the order of the clauses, unless otherwise specified.
4.4One specimen shall be submitted to all the tests.
4.5 In general all the tests are made on each type of control gear or,where a range ofsimilar control gear is involved for each rated wattage in the range or on a representativeselection from the range as agreed with the manufacturer.
4.6 The tests shall be made under the conditions specified in Clause A.1.Since up to nowdata of LED modules are not published in an lEC standard,they shall be made available bythe LED module manufacturer.”
4.7All control gear covered by this standard shall comply with the requirements ofIEC 61347-2-13.
4.8The tests shall be carried out with the length of the output cable of both 20 cm and200 cm unless otherwise declared by the manufacturer.
5 Classification
5.1 Classification according to the loada) Single value load control gear
This type of control gear is designed for use with one specific output wattage only,whichmay be dissipated by one or more LED modules.
b) Multiple value load control gear
This type of control gear is designed for use with one or more LED modules with a totalload within the declared wattage range.
5.2Classification according to the output voltage
a)Control gear having a stabilised output voltage
b) Control gear without a stabilised output voltage
5.3Classification according to the output current
a)Control gear having a stabilised output current
b)Control gear without a stabilized output current
6Marking
6.1 Mandatory marking
6.1.2 ln addition to the above mandatory marking, the following information shall either begiven on the control gear or made available in the manufacturer’s catalogue or the like:
a) if applicable: limits of the permissible temperature range;
b) if applicable: an indication that the control gear has a stabilised output voltage;
c) if applicable: an indication that the control gear has a stabilised output current;
d) if applicable: an indication that the control gear is suitable for operation with a mainssupply dimmer;
e) if applicable: an indication of the operation mode, e.g. phase control.IEC 62384 pdf download.