Home>IEC standards>IEC 62384-2020 pdf free

IEC 62384-2020 pdf free

IEC 62384-2020 pdf free.DC or AC supplied electronic controlgear for LED modules – Performance requirements.
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies, For undated references, the latest edition of the referenced document (including any amendments) applies.
IEC 61347-1, Lamp controlgear — Part 1: General and safety requirements
IEC 61347-2-13, Lamp controlgear — Part 2-13: Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules
3 Terms and definitions
For the purposes of this document, the terms and definitions given in IEC 61347-1 and the following apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
• IEC Electropedia: available at http://www.electropedia.org/
• ISO Online browsing platform: available at http://www.iso.orglobp
3.1 total circuit power
total power dissipated by controlgear and LED module(s) in combination, at rated supply voltage of the controlgear and at the highest rated output load
3.2 circuit power factor A ratio of the measured circuit power to the product of the supply voltage (RMS) and the supply current (RMS)
3.3 controlgear for LED module circuitry with high input capacitance
controlgear suitable for LED modules which present high capacitance connected directly or indirectly to the input terminals
Note I to entry: Examples are LED modules with switch mode power supply conversion circuits, like buck or boost regulators
Note 2 to entry: Typically. capacitances above 100 nF are considered high capacitance.
3.4 controlgear for LED module circuitry with low input capacitance controlgear suitable for LED modules which present low capacitance or no capacitance connected directly or indirectly to the input terminals
Note 1 to entry: Examples are LED modules with only LEDs or with logic circuits intended for thermal protection, but not directly modifying the power supplied by the controlgear. or linear voltage regulators.
Note 2 to entry: Typically, capacitances of 100 nF and below are considered low capacitance.
4 General notes on tests
4.1 The tests given in this document are type tests.
The requirements and tolerances permitted by this document are based on testing of a type test sample submitted by the manufacturer for that purpose. In principle this type test sample should consist of units having characteristics typical of the manufacturer’s production and be as close to the production centre point values as possible.
NOTE It can be expected with the tolerances given in this document that products manufactured in accordance with the type test sample will comply with this document for the majority of the production. Due to the production spread however, it is inevitable that there will sometimes be products outside the specified tolerances. For guidance on sampling plans and procedures for inspection by attributes, see IEC 60410.
4.2 For tests which are carried Out with a LED module or LED modules, this (these) LED module(s) shall fulfil the following requirements:
The power of the LED module(s) when measured at its (their) rated voltage or rated current (direct current and/or alternating current) shall not differ from the rated power by more than  +6 % and – 0 %.
4.3 The tests shall be carried out in the order of the clauses, unless otherwise specified.
4.4 One specimen shall be subjected to all the tests.IEC 62384 pdf free download.